Mikrotron EOSENS GE CAMERA Specifikace Strana 1

Procházejte online nebo si stáhněte Specifikace pro Bridge kamery Mikrotron EOSENS GE CAMERA. Mikrotron EOSENS GE CAMERA Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 37
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
EOSENS
®
GE CAMERA MANUAL
• HIGH SPEED CMOS CAMERA • HIGH SENSITIVITY
EoSens GE Camera Manual Rev. 1.14
Camera-Firmware: B2.02-V1.15-F1.09
Camera ID: MC1364-65
Functions described in this manual may not be available with firmware versions prior than above mentioned.
Information presented in this publication has been carefully checked for reliability; however, no responsibility is
assumed for inaccuracies. The information contained in this document is subject to change without notice.
Copyright 2010 Mikrotron GmbH
Mikrotron GmbH
Landshuter Str. 20-22
D-85716 Unterschleissheim
Germany
Tel.: +49 89 726342 00
Fax: +49 89 726342 99
www.mikrotron.de
Zobrazit stránku 0
1 2 3 4 5 6 ... 36 37

Shrnutí obsahu

Strany 1 - GE CAMERA MANUAL

EOSENS® GE CAMERA MANUAL • HIGH SPEED CMOS CAMERA • HIGH SENSITIVITY •EoSens GE Camera Manual Rev. 1.14Camera-Firmware: B2.02-V1.15-F1.09Camera

Strany 2 - Table of contents

Getting started EoSens GE Camera Manual4 Getting startedBefore starting to operate the camera, make sure that the following equipment is available: C

Strany 3 - EoSens GE Camera Manual

Initial setup EoSens GE Camera Manual5 Initial setupThe EoSens is delivered with initial parameters and therefore does not need to be configured via t

Strany 4 - 1 General

Initial setup EoSens GE Camera Manual5.5 User profilesThe user can store up to four User Profiles in non volatile memory. All load or write commands e

Strany 5

Configuration EoSens GE Camera Manual6 ConfigurationThe content of all EoSens registers is called a profile. There is space in non volatile memory for

Strany 6 - Attention, Warning

Configuration EoSens GE Camera Manual6.1 GenICam® command interfaceGenICam® commands are used to change camera parameters.6.1.1 Command overviewBeside

Strany 7 - 2 Introduction

Configuration EoSens GE Camera Manual6.2 Image size and position6.2.1 Setting the ROI, commands: OffsetX, OffsetY, Width and HeightImage size and posi

Strany 8 - 2.4 Using the camera

Configuration EoSens GE Camera Manual6.2.3 Invert readout in x- and or y-direction, commands: ReverseX, ReverseYCommands: ReverseX, ReverseYDescriptio

Strany 9 - 3 Hardware

Configuration EoSens GE Camera Manual6.3 Framerate and shutter6.3.1 Setting the framerate, command: AcquisitionFrameRateAbsCommand: AcquisitionFrameRa

Strany 10 - 4 Getting started

Configuration EoSens GE Camera Manual6.3.4 Non destructive readout for multi exposure, command: NonDestructiveReadoutCommand: NonDestructiveReadoutRan

Strany 11 - 5 Initial setup

Configuration EoSens GE Camera Manual6.4.1 Type of exposure, command: ExposureModeThe EoSens can expose the images in free run mode or with an externa

Strany 12 - 5.6 PowerUpProfile

EoSens GE Camera ManualTable of contents1 General...

Strany 13 - 6 Configuration

Configuration EoSens GE Camera Manual6.5 Image quality6.5.1 Digital gain, command: DigitalGainCommand: DigitalGainRange : <xxxx> = 0 or 0400 ..

Strany 14 - 6.1 GenICam

Configuration EoSens GE Camera Manual6.5.3 FPN correction, command: FPNEnableCommand: FPNEnableDescription: With this command the column FPN (fixed p

Strany 15 - 6.2 Image size and position

Configuration EoSens GE Camera Manual6.6 Other6.6.1 In frame counter, command: InFrameCountCommand: InFrameCountDescription: If a sequence of frames i

Strany 16 - ReverseX, ReverseY

Configuration EoSens GE Camera Manual6.6.3 Setting threshold mode, command: GrayThreshold (optional feature)Command: GrayThresholdEnableand: GrayThres

Strany 17 - 6.3 Framerate and shutter

MC Control Tool EoSens GE Camera Manual7 MC Control ToolThe MC Control Tool must be installed on a Windows PC. (Win9x, WinNT, Win2K, WinXP) by means o

Strany 18 - 6.4 Exposure control

Firmware EoSens GE Camera Manual8 FirmwareThe camera possesses programmable devices, which are working with some firmware packages

Strany 19

Firmware EoSens GE Camera Manual8.3 Firmware update procedureBefore you disable the loaded firmware please ensure that you have an adequate applicatio

Strany 20 - 6.5 Image quality

Technical Data EoSens GE Camera Manual9 Technical Data9.1 OverviewMC1364MC1365MonochromeBayer FilterNumber of pixel 1280 x 1024Pixel size 14 x 14 µmAc

Strany 21 - FPNEnable

Technical Data EoSens GE Camera Manual9.2 Sensor defect specificationsParameter Description LimitBrightPixAmount of bright pixels (response higher the

Strany 22 - 6.6 Other

Technical Data EoSens GE Camera Manual9.3 Spectral responseThe charts below show the sensitivity of the monochrome and the color sensor with a bayer p

Strany 23

EoSens GE Camera Manual6.6.5 Read firmware version, command: FirmwareVersion...

Strany 24 - 7 MC Control Tool

Technical Data EoSens GE Camera Manual9.4 Bayer pattern filterThe EoSens color camera has a bayer pattern filter on the sensor glass lid. To get the c

Strany 25 - 8 Firmware

Technical Data EoSens GE Camera Manual9.5 Connector pinning9.5.1 Gigabit Ethernet ConnectorConnector type: RJ45 female9.5.2 Circular power connector,

Strany 26 - 8.3 Firmware update procedure

Technical Data EoSens GE Camera Manual9.6 Timing diagrams9.6.1 Timed (Free run with electronic shutter)In this mode framerate and exposure time is con

Strany 27 - 9 Technical Data

Technical Data EoSens GE Camera Manual9.7 Mechanical dimensions

Strany 28

Quick start guide for GigE Vision® EoSens GE Camera Manual10 Quick start guide for GigE Vision®This guide describes the basic steps to set up a connec

Strany 29 - 9.3 Spectral response

Quick start guide for GigE Vision® EoSens GE Camera Manual10.3 Configure the network card• Go to the network property page and set the IP and the subn

Strany 30 - 9.4 Bayer pattern filter

Quick start guide for GigE Vision® EoSens GE Camera Manual10.4 Connecting using the GEV Player• Start the GEV player(Start->Programs->Pleora Tec

Strany 31 - 9.5 Connector pinning

Quick start guide for GigE Vision® EoSens GE Camera Manual10.5 Camera configuration• Click GEV Device control to configure the camera.

Strany 32 - 9.6 Timing diagrams

General EoSens GE Camera Manual1 General1.1 For customers in the U.S.A.This equipment has been tested and found to comply with the limits for a Class

Strany 33 - 9.7 Mechanical dimensions

General EoSens GE Camera Manual1.5 Declaration of conformity Manufacturer: Mikrotron GmbHAddress: Landshuter Str. 20-2285716 UnterschleissheimGermanyP

Strany 34 - 10.2 Install the EBus Driver

General EoSens GE Camera Manual1.6 Warranty NoteDo not open the body of the camera. The warranty becomes void if the body is opened.1.7 Remarks, Warni

Strany 35

Introduction EoSens GE Camera Manual2 IntroductionThe CMOS high speed camera EoSens is a high resolution camera with 1280x1024 pixel. Benefits of CMO

Strany 36

Introduction EoSens GE Camera Manual2.3 Differences between the camera typesThe CMOS cameras are available in different versions depending on the supp

Strany 37 - 10.5 Camera configuration

Hardware EoSens GE Camera Manual3 Hardware3.1 GigE Vision® interfaceGigE Vision® is designed for digital cameras in machine vision applications. This

Komentáře k této Příručce

Žádné komentáře