Technical Data EoSens GE Camera Manual
9.6 Timing diagrams
9.6.1 Timed (Free run with electronic shutter)
In this mode framerate and exposure time is controlled by the camera. At the strobe output (in power connector)
there is a high signal while the camera exposes a picture.
9.6.2 Trigger width (Pulsewidth mode)
In this mode framerate and exposure time is controlled by the TRIG_IN (in power connector) input. The time
t_min (that defines the framerate) must not be smaller than t_out (which is the output time for one frame).
9.6.3 Trigger Controlled (External sync with internal timer)
In this mode the framerate is controlled by the TRIG_IN while the exposure time is controlled by the camera.